Malaysia Leading Online Shopping Marketplace

  • Jual Dengan Kami
  • Ikut Kami Di
  • Notifikasi
    Notifikasi Baharu
  • Help
  • Daftar
  • Log Masuk

Sila Log Masuk untuk melihat produk.

RCYAGO NEW 4 in 1 water quality tester PH meter ORP tester H2 hydrogen meter with temperature meter
No Rating Yet
0 Dijual

/ Per Produk

Penghantaran

Penghantaran Dari
Mainland China
Anggaran Penghantaran
Nov 22, 2024 - Dec 13, 2024

Warna

Sila pilih variasi produk terlebih dahulu

Kuantiti

9937 Unit lagi
Jumlah
RM 104.57
Gambaran Kedai
Home Life Hall
3 hours ago
Produk 87281
Pengikut 12
Penilaian 4.5
Sertai 3 Months Ago
Kadar Pembatalan 0%
Spesifikasi Produk
Category
: Automotive & Motorbike  >  Interior Accessories  >  Steering Wheels & Accessories
Brand
: NoBrand
Model
: Not Specified
SKU
: 20904395721
Dimension (Length x Width x Height)
: 10.00 x 15.00 x 20.00
Weight(kg)
: 0.6
Manufacturing Country
: Not Specified
Warranty Type
: No Warranty
Warranty Value
: -
Warranty Description
: -
Hantar Dari
: Mainland China

Deskripsi Produk

RCYAGO NEW 4 in 1 water quality tester PH meter ORP tester H2 hydrogen meter with temperature meter

[Wide Application] Ideal for household and laboratory pH testing applications, including drinking water, swimming pool, pond, beer brewing, kombucha, aquariums, hydroponics, laboratory, food processing,

Generally, the H2 of hydrogen-rich water on the market is 800ppb~1600ppb, and the H2  of general drinking water is basically 0.

Hydrogen-rich water is weakly alkaline water with a PH value between 7.0 and 9.5. Ordinary drinking water is generally at 7.0, which is neutral.

The ORP of hydrogen-rich water is generally around -300MV~-500MV, which is slightly different from the water quality in different regions.

 

Measuring Range:                                             Accuracy:

PH Range: 0.01~14.00 PH                                                                         PH: ±0.05PH
ORP: ±999mV;                                                                                           ORP: ±2mV;
H2: 0-2400 ppb, 0.01-2.400ppm( 1ppm = 1000ppb);                               H2: ±10ppb; 10ppm;               
Temperature: 0.1-60℃(32.0-140.℉)                                                          Temperature: ±0.5

Features:

  • Pocket size, light weight, and portable with backlight

  • PH Clibration: Three points calibration( 6.86, 4.01,9.18)

  • ATC Function: The p can accurately determine the PH value of the sample in the temperature range of 0℃-60℃(32℉-140℉),so as to solve the inaccurate measurement caused by the changing temperature
  • Batteries: 3*1.5V LR44 battery(Included)
  • LCD Display

  • Hold: Data lock
  • Waterproof level: IP67 waterproof

Hydrogen water is so benficial to our health, it can gie us:

1. weight control, 2 helps sleep,3.healthy skin, 4.improve sub-health, 5.anti-aging.

Wife application:

Suitable for water source and laborotories, breeding farms, farmland irrigation, Aquarium Industry and so on.

How to Use:

MODE/CAL: The MODE button is for switching from testing PH/H2/ORP/Temperature ;The CAL button is for calibrating the PH value(6.86, 4.00,9.18). Press this button can switch to this two ways.
HOLD/Temperature button: Hold button is for recording the value you are testing; and Temperature button is for testing the temperature of the water. Press this button can switch to this two ways.

How to calibrate PH: 

1.Turn on pH meter by pressing ON/OFF button
2. Dissolve each buffer solution in 250 mI of distilled water to prepare the solution
3. Immerse the electrode into the pH 6.86 solution.
(under the temperature of 25)
4. Press the "MODE/CAL" (calibration) button for 5 seconds and release
- Display will start flashing 6.86
- Wait until the display stops flashing.
Rinse the electrode with distilled water and dry it with flter paper.

5. Immerse the electrode in pH 4.00 solution,
- Press "TEMP/CAL" button for 5 seconds , screen show 6.86 then press and release immediately second time .,screen will display 4.00 .
- Reading will start flashing 4.00.
- Wait until display stops flashing
Rinse and dry the electrode with distilled water as before.

6. Immerse the electrode in pH 9.18 solution, wait few seconds until the display is stable
- Press "TEMP/CAL" button for 5 seconds , screen show 6.86 , then press and release immediately second time , screen will display9.18
- Reading will start flashing 9.18.
- Wait until display stops flashing
Rinse and dry the electrode with distilled water as before.

How to calibrate ORP?

1.Turn on pH meter by pressing ON/OFF button
2. Dissolve 256mV ORP buffer solution in 250 mI of distilled water to prepare the solution

3. Immerse the electrode into the ORP solution

4. When the value each to the value in normal accuracy rate, it's OK.

Question&Answer:

Q1: Can I test the H2 content of every kind of water? 

A1: This pen can only test the H2 generated by Hydrogen water cup; The H2 of ordinary water is almost 0, so it can't have such a reaction;

Q2: When to test the H2?

A2: We should test the H2 after the water has completed the electrolysis process in the Hydrogen cup.

Q3: Whether this product has ATC?

A3: Yes, in the temperature of 0℃-60℃(-32℉-140℉)

11.jpg14.jpg13.jpg

10.jpg

 

 

Penilaian produk
- / 5.0
Copy Link
  • 0 Troli Membeli-belah
  • Wishlist
  • Pusat Kupon
  • Informasi
  • Chat
  • Log Masuk / Daftar
  • What's In The Box
  • Kongsi
  • Kembali
  • Kembali Ke Atas
  • ©2024 PG Mall Sdn. Bhd. 200801035285 (836625-K). All Rights Reserved.