Note:
This gauge is with stepper motor, so it is not a problem if the needle not be zero, and the needle will be zero after you connect the all wire and power on it.
Please note that the meter will not work if only the black and red wires are connected. Be sure to connect the white or orange wire!
Note:
1:Highly Recommended professional installation(Not teach you how to connect the O2 Oxygen sensor),theO2 Oxygensensor is not universal ,only for theSpecificHYUNDAI models(Detailed description below):
2:Narrowband Oxygen Sensor O2 Rear:
OEM Ref Part Number:392102262039210-22620
Fitment :
For Hyundai Elantra ,2.0L,rear,all 2001-2002
For Hyundai Elantra ,2.0L ,rear ,all ,manual trans 2003-2006
For Hyundai Accent ,All ,rear 2001-2006
For Hyundai Tiburon ,2.0L ,rear 2003-2006
2:The output voltage of this O2 Oxygensensor is only two:0.1V and 0.9V,so it only can let the gauge to show the working status :"LEAN"and "RICH".
Other Parameters:
1:60MM Air Fuel gauge:
Condition:100% New.
Power:DC 12V Professional.
Diameter:2.5"/60mm.
Note:Easy Installation With Users Manual In English,Professional installation is Highly Recommended.
Universal fit for: 12Volt Cars
Onegauge With Two backlight(Whiteand Amber light)
Package include:
1 x Air Fuel Gauge
1 X Cable
1X English Manual
1XO2 Oxygen sensor
Gauge Function Settings:
-
Buzzing Sound
If you want to cancel the buzzing sound, just restart the power supply and hold the button until the buzzing sound disappears, then release the button. Vice versa. (Need to operate before the meter self-check is completed)
-
Clear the PEAK Value
After completing the Self-check, press the button and release, the PEAK lights up (blue light). Then hold the button again for 3 seconds, when the PEAK light flashes, release the button, PEAK value is cleared, the pointer will returns to zero after about 3 seconds.
-
Set Alarm Points and Cylinder
After self-check, hold the button for 5 seconds, the pointer lights flicker, loosen, and then press the button to set the alarm point (Press the button continuously and fleetly for fine setting, press and hold the button continuously for quick setting). After about 5 seconds, the pointer automatically returns to zero, you can then set the next Step.
After self-check or after the pointer returns to zero, hold the button for 10 seconds, the pointer lights flicker, loosen, and then press the button to set the cylinder, loosen, after 5 seconds, the pointer automatically returns to zero, you can set the next step.
When the meter reaches the alarm value, the lights will flicker continuously.