【Excellent Product】DY4100 Digital Ground Resistance Tester can test earth resistance of various earth systems including power systems, electric
【Features】More complete functions, higher accuracy, more convenient and reliable for operation and more suitable for outdoor use with dust and wet proof structure.
【Good Design】 Digital ground resistance tester with LED LCD screen, potenial pole, grounding pole, current pole, voltage pole ect. Low battery warning.
It can test the ground resistance of various ground systems, including power systems, electrical equipment, lightning conductors as well as the resistance value of the low resistance conductor and the AC voltage test.
【Test】Lightning conductors as well as resistance value of low resistance conductor and AC voltage test. Overvoltage protection, data hold.
【Data】Earth Ground Resistance:0/20/200/2000Ω; Earth Voltage:0~30V +/-3% +
Package Included:
1 x DY4100 soil resistance tester
2 x auxiliary earth bar
1 x wire test
1 x single test lead
1 x instruction manual
1 x tool bag
Data hold, low battery warning
Complete with test leads, auxiliary earth bars, (without battery)
Specification:
Mode: DY4100
Resolution: 0.01 Ω
Data retention: yes
LED operation indicator: yes
Function symbol display: yes
Battery Warning: yes
Earth voltage: 0-30V ± (3% + 5)
Earth resistance: 0/20/200/2000 Ω ± (2% + 3)
Voltage range: can support 300V AC (1 minute)
Resistance range: can support 200V AC (10 seconds)
Grounding resistance test requirements:
a. AC working mass, the earthing resistance must not exceed 4Ω.
b. safe grounding, the grounding resistance must not be greater than 4 Ω.
vs. the earthing resistance of the lightning protective earth must not exceed 100 Ω.
re. For joint earthing of shielded systems, the earthing resistance must not exceed 10 Ω.
e. Grounding operating in direct current, the grounding resistance must be determined according to the specific requirements of the computer system.
Ground tension measurement:
Please turn the dial switch on the grounding voltage file "EV" and connect the test line according to the grounding test table.
The earth voltage will be automatically displayed. Please make sure that the earth voltage is ≤10V. If the local voltage is> 10V.
the measurement value of the earthing resistance may cause an error. At this point, the electrical equipment concerned can be switched off
to reduce the grounding voltage before measurement.
Earth resistance measurement:
Precise measurement (with the test leads fitted) to drill the grounding pins P and C to the ground depth.
They are arranged in a straight line with the grounding equipment and are spaced 5 to 10 meters apart.
(Note: Make sure the grounding pins are inserted into the moist soil. If the ground of the grounding nail is dry, it is necessary to add water or stone or sand to wet and test)