FLUKE 17B+ 600V CATIII Digital Multimeter with Temperature & Frequency
No Rating Yet
0 Dijual

/ Per Produk

Penghantaran

Penghantaran Dari
Mainland China
Anggaran Penghantaran
Oct 05, 2024 - Oct 26, 2024

Warna

Color Family

Sila pilih variasi produk terlebih dahulu

Kuantiti

10 Unit lagi
Jumlah
RM 1125
Gambaran Kedai
Home Life Hall
8 hours ago
Produk 87315
Pengikut 5
Penilaian 4
Sertai 2 Months Ago
Kadar Pembatalan 0%
Spesifikasi Produk
Category
: Kitchen & Dining  >  Kitchen Tools  >  Thermometers & Timers
Brand
: NoBrand
Model
: Not Specified
SKU
: 103972698
Dimension (Length x Width x Height)
: 10.00 x 15.00 x 20.00
Weight(kg)
: 0.6
Manufacturing Country
: Not Specified
Warranty Type
: No Warranty
Warranty Value
: -
Warranty Description
: -
Hantar Dari
: Mainland China

Deskripsi Produk

17B1.jpg



17B2.jpg



17B3.JPG



17B4.JPG



17B5.JPG



Fluke quality is always within your reach



Your job requires that you have a rugged, reliable and accurate digital multimeter.? The Fluke 17B+ digital multimeter does all that and more.? Common basic electrical measurements plus temperature, frequency and duty cycle.? Easy to use with one hand, even with gloves on, the Fluke 17B+ offers everything you need.



Accuracy Specifications



Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).





















































































































Function Range Resolution Accuracy
AC volts

(40 Hz to 500Hz)1
4.000 V

40.00 V

400.0 V

1000 V
0.001 V

0.01 V

0.1 V

1 V
1.0 % + 3
DC volts 4.000 V

40.00 V

400.0 V

1000 V
0.001 V

0.01 V

0.1 V

1 V
0.5 % + 3
AC millivolts 400.0 mV 0.1 mV 3.0 % + 3
DC millivolts 400.0 mV 0.1 mV 1.0 % + 10
Diode test2 2.000 V 0.001 V 10%
Resistance

(Ohms)
400.0 Ω

4.000 kΩ

40.00 kΩ

400.0 kΩ

4.000 MΩ

40.00 MΩ
0.1 Ω

0.001 kΩ

0.01 kΩ

0.1 kΩ

0.001 MΩ

0.01 MΩ
0.5 % + 3

0.5 % + 2

0.5 % + 2

0.5 % + 2

0.5 % + 2

1.5% + 3
Capacitance3 40.00 nF

400.0 nF

4.000 μF

40.00 μF

400.0 μF

1000 μF
0.01 nF

0.1 nF

0.001 μF

0.01 μF

0.1 μF

1 μF
2 % + 5

2 % + 5

5 % + 5

5 % + 5

5 % + 5

5 % + 5
Frequency1

Hz

(10 Hz – 100 kHz)
50.00 Hz

500.0 Hz

5.000 kHz

50.00 kHz

100.0 kHz
0.01 Hz

0.1 Hz

0.001 kHz

0.01 kHz

0.1 kHz
0.1 % + 3
Duty Cycle1 1 % to 99 % 0.1 % 1 % typical 4
AC current μA

(40 Hz to 400 Hz)
400.0 μA

4000 μA
0.1 μA

1 μA
1.5 % + 3
AC current mA

(40 Hz to 400 Hz)
40.00 mA

400.0 mA
0.01 mA

0.1 mA
1.5 % + 3
AC current A

(40 Hz to 400 Hz)
4.000 A

10.00 A
0.001 A

0.01 A
1.5 % + 3
DC current μA 400.0 μA

4000 μA
0.1 μA

1 μA
1.5 % + 3
DC current mA 40.00 mA

400.0 mA
0.01 mA

0.1 mA
1.5 % + 3
DC current A 4.000 A

10.00 A
0.001 A

0.01 A
1.5 % + 3
Temperature 50 °C- 400 °C

0 °C- 50 °C

-55 °C- 0 °C
0.1C 2 % ± 1 °C

± 2 °C

9 % ± 2 °C
Backlight - - Yes
1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.

2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.

3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).

4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.


?












































Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,

50 Hz or 60 Hz
-
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz -
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,

50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz -
1 106 V Hz Max


?




























































































General Specifications
Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C
Relative Humidity
Operating humidity Non-condensing (<10°C)

≤90% RH at 10 °C to 30 °C;

≤75% RH at 30 °C to 40 °C
40 MΩ range

≤80% RH at 10 °C to 30 °C;

≤70% RH at 30 °C to 40 °C
Altitude
Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.

11A, 1000V Fast Fuse, Fluke specified part only.
Size (HxWxL) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment IEC 61326-1: Portable
Electromagnetic compatibility Applies to use in Korea only
Class A equipment (industrial broadcasting & communication equipment)1

1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or

user should take notice of it. This equipment is intended for use in business environments and is not to be

used in homes.
Penilaian produk
- / 5.0
Copy Link
  • 0 Troli Membeli-belah
  • Wishlist
  • Pusat Kupon
  • Informasi
  • Chat
  • Log Masuk / Daftar
  • What's In The Box
  • Kongsi
  • Kembali
  • Kembali Ke Atas
  • ©2024 PG Mall Sdn. Bhd. 200801035285 (836625-K). All Rights Reserved.