Product overview: Fluke 107 Palm-sized, CAT III Digital Multimeter
The Fluke 107 is a compact, palm size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test. For everyday applications where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time. With a CAT III 600 V safety rating, you don’t need to compromise safety. The Fluke 107 offers a comfortable grip, weighs only 200 g, and is easy to carry. Fluke 107 measurement test functions
-
AC and DC voltage
-
AC and DC current
-
Resistance
-
Capacitance
-
Diode
-
Frequency and duty-cycle
Fluke 107 comes ready to workThe Fluke 107 comes with a TL75 Hard Point? Test Lead Set. It’s one pair (red, black) of 48 inch (1.22 meter) test leads with right-angle, shrouded banana plugs. The meter also includes a SmartStrap? intelligent magnetic multi-purpose lanyard that lets you hang the Fluke 107 from any ferrous surface or support the meter at an angle for easy viewing.
Specifications
Accuracy Specifications
|
Function
|
Range
|
Resolution
|
Accuracy
|
AC Volts
(40 Hz to 500Hz)1
|
6.000 V
60.00 V
600.0 V
|
0.001 V
0.01 V
0.1 V
|
1.0 % + 3
|
DC Volts
|
6.000 V
60.00 V
600.0 V
|
0.001 V
0.01 V
0.1 V
|
0.5 % + 3
|
AC Millivolts
|
600.0 mV
|
0.1 mV
|
3.0 % + 3
|
Diode Test2
|
2.000 V
|
0.001 V
|
10 %
|
Resistance
(Ohms)
|
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
|
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
|
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
|
Capacitance3
|
50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
|
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
|
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
|
Frequency4
Hz
(10 Hz – 100 kHz)
|
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
|
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
|
0.1 % + 3
|
Duty Cycle4
|
1 % to 99 %
|
0.1 %
|
1 % typical5
|
AC Current
(40 Hz to 200 Hz)
|
4.000 A
10.00 A
|
0.001 A
0.01 A
|
1.5 % + 3
|
DC Current
|
4.000 A
10.00 A
|
0.001 A
0.01 A
|
1.5 % + 3
|
-
All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
-
Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
-
Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
-
All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
-
Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %
|
|
|
|
|
|
AC Volts
|
600 V1
|
>10 MΩ <100 pF2
|
>60 dB at dc,
50 Hz or 60 Hz
|
?
|
AC Millivolts
|
600 mV
|
|